Fancy "X" ? (ex Twitter) contact me NOW! @FranckGuttentag

***** SOLD ALREADY ***** SOLD ALREADY *****

BEST SYSTEMS FOR SALE HERE: Rev. February 2025
There is currently one system available below:
OUR BEST OFFER in EUROPE, clearance sale available NOW:
Siemens 2006 LITHOSTAR Modularis Lithotripter for sale with:
Siemens Modularis Uro patient table. No C-arm.
Less used: only 1,5 million shots! (around 300 patient treatments)
The system has been lastly PMed and controlled by a Siemens Engineer.
All field service reports available on demand.
In good clinical condition. Ready for treatments.
In good aspect, no bumps, no scratches.
Note: We will let it go for only EURO 4,000.00 outright!
Crating additional. The system can be inspected before shipping.
Available NOW IN EUROPE. Are you ready??? Don't miss out!
Further details: email us, thank you.

LITHOSTAR MODULARIS AVAILABLE NOW! BEST OFFER OF THE MOMENT !
Remember: You CAN get that system above for only 4,000.00 euros outright!!!
Below: inventory listing for
Lithotripter Modulith SLX classic: (and F2)
- airbag, lateral p/n 4616
- flat washer for airbag p/n 5134
- o-ring for airbag mount p/n 4509
- central airbag (on top of coil) p/n 10036
- coil kit p/n 10719 for SLX classic; not in stock yet
- second hand coil SLX classic: p/n 1235; not in stock yet
- NEW: coils for SLX classic p/n 1235, not in stock yet, eur 5,930.00 outright
contact flange p/n 6283.
shock wave control board p/n 13373 never used for SLX-F2
HV cable p/n 4578; not in stock yet
coupling cushion p/n 11284; not in stock yet
coupling cushion p/n 45107; no longer available
Inline snap-in catch with probe 7.5 Mhz p/n 5370
Filter, element p/n 4230
Filter, inline p/n 8905
operating panel p/n 5790
cable assy, operating panel p/n 5830
patient foil p/n 3728; not in stock yet
parvex pump RS320 CR1034 p/n 4062
degassing pump p/n 4063
air pump, small type p/n 4319
solenoid, airvalve #2 p/n 4312
limit switch TH unlocked motor p/n 3795
switch Z-speed p/n 3796
switch TH locked 2 p/n 3797
switch TH unlocked motor p/n 4534
dummy stone p/n 3398 for both SLX and SLK
Thyratron tube CX1722G/2 p/n 1254 for both Modulith SLK and SLX
water additive SLX p/n 6038
water pipe p/n 922
water pipe p/n 946
water pipe p/n 1831
water pipe p/n 1842
water hose Tigon diam 25, p/n 11573
water hose diam 25, p/n 11647
water hose diam 20, L=165, p/n 4273
water pipe L=680 mm p/n 4274
handswitch p/n 8469
original Bussmann fuse 56 Amps - ET56 - BS88:4
grey and green paints for SLX p/n & large quantity: contact us.
Not exhaustive - Numerous other parts in stock....

Most common Boards: (SLX)
Controller boards: (SLX)
- CTU Charge Trigger Unit, SLX p/n 1896 (Not in stock)
- shock wave control board p/n 13373 for SLX-F2
Imaging system: (SLX)
- x-ray imaging system: not available at the moment
ULTRASOUND:
- Inline / snap-in catch probe w/ transducer p/n 5370 (used item ok)
- ultrasound imaging system: Kontron S880 & S440 power supply
Padding (SLX)
- main pillow p/n 3440
- additional pilow p/n 4418
- foot pillow (a) p/n 4369
- foot pillow (b) p/n 4370
- chest pillow p/n 5717
- head pillow p/n 4400
- key pillow p/n 4375
- triangle pillow p/n 4376
Monitors, Video graphic printer & Miscel: (SLX)
- Not in stock at the moment; please check again soon!
Contact: lithotripter@europe.com
Tutorials:
x-ray focus check / calibration: how to check the x-ray calibration
Water refilling level
Documentation, Literature and studies:
Here you find some literature about treatments done with the SLX and SLK ESWL machines.
|
We are currently SEARCHING for our customers 2nd hand lithotripters TO PURCHASE:
Dornier and Siemens in working conditions. Preferred location: Europe.
Storz lithotripters SLK, SLX, SLX-F2, SL1, etc. (accepted in average conditions)
Also looking for loose parts for Dornier Compact Delta series and Siemens Lithostar.
Contact me by email for a quick response and a very good offer in hours!
Below: inventory listing for
Lithotripter Modulith SLK Classic:
- coil p/n 8135 for SLK
- coupling cushion p/n 9074, available in the PM kit only
- mounting ring for coupling cushion p/n 9067
- water bottle with hose and clamp p/n 8008 not available
- control panel p/n 7557
- cable, control panel p/n 7543
- cable, camera extension p/n 15759
- cable inlet, mains for SLK
- compact PS2 keyboard, G84-4100 p/n KL01436
- coupling for stepper motor p/n 9072
- degassing pump p/n 8379
- fan for water radiator p/n 3857
- Filter, element p/n 4230, available in the PM kit only
- Filter, inline p/n 8905, available in the PM kit only
- hydraulic oil p/n 13204
- hydraulic unit p/n 12184
- mains cable for oil compressor p/n 7381
- o-ring p/n 4509 for SLK
- o-ring p/n 7888 for SLK
- ultrasound foil p/n 10205, available in the PM kit only
- retaining ring for ultra. foil p/n 10211, available in the PM kit only
- sealing washer p/n 7745 for SLK
- sealing washer p/n 10897 for SLK
- shock wave release button p/n 7949 for SLK
- suspension, cable p/n 9696 for SLK
- switch belows min p/n 7417 for SLK
- switch belows max p/n 7416 for SLK
- switch, brake p/n 11768
- tooth belt for stepper motor p/n 8193 for SLK
- turning knob p/n 7445
- Thyratron tube CX1722G/2 p/n 1254
- Grey paint Ral 7001 p/n 7386 for SLK and SLX
- Grey paint Toyo-011 p/n 2211 for SLK and SLX
- Not exhaustive - Numerous other parts in stock....
Controller boards: (SLK)
- control panel p/n 7557
- main controller board p/n 8970
Special offers below on Panel PCs and cameras: contact us for more info.
- Panel PC / lithotrack screen p/n 12017 for SLK, one item in stock.
- Panel PC other available p/n 12344; 12377; 18355
- Lithotrack camera p/n 10352 for SLK, several items never used in stock!
PCCU for SLK:
- PCCU / Pulse Current & Charging Unit p/n 10038 for SLK
Imaging system: (SLK)
- ultrasound transducer Aloka-9102U-3.5 Mhz
other parts for your stocking here:
Just contact us and find out what you need!
We provide most any ESWL parts on most any models!
Liquidation sale on service coils SLK p/n 8135
2M coils SLK, OUTRIGHT price EURO 1,500.00 per unit, warranty 30 days granted,
All prices in Euro and do not include P&P (post and packing) which are additional.
SPECIAL OFFER 25% IMMEDIATE DISCOUNT on the 2nd item.
Don't miss out!!! Contact us!
- Our service coils are used more or less 12,000 SW each, tested, 30 days warranty granted. Warranty can be extended on demand.
- more information: contact Franck Guttentag
Best offer on PM kits for SLK: Available in stock !!
PM kit complete SLK outright price EURO 350.00 only! (including coupling cushion, US foil and retaining ring, element filter and inline filter) Payment in Sterling and USD not available. All prices outright, charged in Euro and do not include P&P (post and packing) which are additional.
NEW: Lithotripter Minilith SL1 section:
- service coil p/n 4793 for Minilith SL1, outright Euro 1,200.00
- o-ring for coil (large) p/n 4866
- o-ring for coil (small) p/n 4867
- coupling cushion p/n 7322
- mounting ring for coupling cushion p/n 4634
- US foil p/n 7827
- retaining ring for US foil p/n 7785
- bleeding screw p/n 7090 (m3x5)
- sealing ring for bleeding screw p/n 5062
- water bottle p/n 8008; not available in stock.
- tooth belt (timing belt) p/n 7046
- pulley for tooth belt p/n 6851
- clutch / coupling element p/n 7045
- US transducer probe 7.5 MhzB for Minilith p/n 0630, sold already!
SLK tips for you...
SLK operator's 1st step trouble shooting guide, here are some tips for you:
Machine will not power ON:
- check the mains socket and mains cable
- check the fuses located behind the front door
- check the control panel cable and connection
- turn the mains switch several times to ON / OFF positions
Air bubbles remaining within the therapy head:
- put the machine into the degassing mode (coupling cushion pos. 0 of the control panel) and leave it on its own for at least 2 hours.
Coupling cushion will not inflate properly:
- check the general water level and add some water with the help of the water bottle to reach the correct level
Coupling cushion will not inflate well and machine makes some noise when cushion is being inflated:
- water circuit requires your attention and will need some repair
Water leaking from the therapy head when turned upside down:
- check the ultrasound foil and change it (within the therap head)
Water leakage from the coupling cushion when inflated:
- check the cushion mounting ring or
- coupling cushion needs changing if pierced
Chock wave release becomes erratic at 3 or 4 herts / shots per second:
- check the mains selector and adjust it to fit the mains voltage of the treatment room
Most frequent system error messages (SLK)
E10: stepper motor routine time out; E11: Stepper motor out of limits; E15: Degassing pump not working properly; E16: check the floating valve of expansion bellows; E20: HV circuit problem, check the PCCU; E30 up to E34: check the PCCU; E90: main controller to CAN bus com. problem, check the CP connection; E91: CAN bus disconnected; E92: hardware - software not comatible with each other; E93: CAN bus is OFF; E94: CAN bus failure, check / replace the control panel.
Capacitance of the PCCU
Switch the machine off, wait at least 5 minutes, open up the HV measurement point on the top of the PCCU by unscrewing the cap, then measure directly upon the HV point, value must be 1000 nF, +/- 5%
contact: lithotripter@europe.com
When you get in touch with us:
please do provide your detailed infomation in your email: full name, address, zip code, country, etc. No response will be given to anonymous requests. *Some countries are no longer supported: China, Taiwan, Malaysia, Indonesia, Corea, Japan, war zones genarally speaking. Thank you for your understanding.
Post & Packing:
All prices shown online -or quoted in response- OUTRIGHT and charged in EURO only -OR USD ($) if mentioned- and do not include post and packing. (P & P)
P & P charges VARY, depending on the WEIGHT and SIZE of the parcel and COUNTRY of delivery. (Zone 1 to 7)
PAYPAL FEES are ADDITIONAL and charged FROM 3% UPTO 5 % of the total order value.
Delivery time:
PLEASE BE AWARE that the goods we offer may come from different locations. Most any goods are in stock; others are made to order. This will be confirmed to you.
Your items may sometime arrive at DIFFERENT TIMES in separate packaging.
We aim to get your goods to you as soon as possible, but please allow up to 10 days for the full completion of your order.
Should you have reason to contact us, please quote your Order Reference, company's name & the date of your email of confirmation. Thank you.
For your complete information, we go mainly through Logical Solution Services for our international shipments. They take good care of our equipment for crating and shipping world wide.
Notice: Payment in $ (USD) by wire accepted for complete suystems only!

|